Spectrophotometer BioDrop µLite+

The BioDrop µLite+ has a 0.5 mm microvolume sample port that enables absorbance measurements of 0.5 μl sample volume. The instrument has pre-programmed applications for the measurement of DNA, RNA, oligonucleotides, protein assays, OD600 and a comprehensive menu of common fluorescent dyes for nucleic acids and proteins. Generated data can be stored internally or on a USB stick. The photometer can be operated with a PC and the supplied BioDrop Resolution software.

  • 7"-colour touchscreen
  • No calibration needed
  • Easy cleaning of the sample port with a lint-free tissue
  • Optionally with integrated printer

Spectrophotometer BioDrop µLite+

Spectrophotometer BioDrop µLite+



Biochrom BioDrop µLITE 80-3006-55
PART NO.4AJ-6319282
82238||82414||82201||81159||81030||81319||81831||81074||79427||81490||82199||81462||79898||81973||81781||81974||79302||79642||79560||79485||81657
Min. measured value mOsmol/kg||Absorption||Sensor inputs||Verified calibration||Revolving nosepiece||Height box||Frame colour||Dim. Int. (Ø x H)||Type of product||With sterilisation indicator||Nominal volume funnel||Width mm||Depth mm||Height mm||Variable||Weight kg||Int. width||Capacity||Throughput||Ext. depth||PK
190 ... 1100||0 ... 2.5 A
0 ... 100 %T||±0.01 A + 1.5 % of the reading at 546 nm||<0.5 %T at 220 nm (Nal)/<0.5 %T at 340 nm (NaNO2)|| || ||Xenon|| || ||UV-VIS|| ||280||410||190||280 x 410 x 190 mm||3.55|| ||Mains connection|| || ||1
Biochrom
80-3006-55
BIODROP

Photometer spectro

Photometer

Spectrophotometers

0
6
0
1
Out of Stock
Biochrom BIODROP µLITE Spectrophotometer 80-3006-56
PART NO.4AJ-6319283
82238||82414||82201||81159||81030||81319||81831||81074||79427||81490||82199||81462||79898||81973||81781||81974||79302||79642||79560||79485||81657
Min. measured value mOsmol/kg||Absorption||Sensor inputs||Verified calibration||Revolving nosepiece||Height box||Frame colour||Dim. Int. (Ø x H)||Type of product||With sterilisation indicator||Nominal volume funnel||Width mm||Depth mm||Height mm||Variable||Weight kg||Int. width||Capacity||Throughput||Ext. depth||PK
190 ... 1100||0 ... 2.5 A
0 ... 100 %T||±0.01 A + 1.5 % of the reading at 546 nm||<0.5 %T at 220 nm (Nal)/<0.5 %T at 340 nm (NaNO2)|| || ||Xenon|| || ||UV-VIS|| ||280||521||190||280 x 521 x 190 mm||4|| ||Mains connection|| || ||1